TM-5-5420-202-20-4

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 4 OF 4

OCTOBER 1985

  TM-5-5420-202-20-4 - Page 311 of 534

TM 5-5420-202-20-4
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT
(Sheet 1 of 2)
TOOLS: Slip joint pliers, conduit style, with plastic jaw inserts
Flat-tip screwdriver
SUPPLIES:
Lockwashers (4 required)
Gasket
REMOVAL:
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or
kill you.
NOTE
Removal procedures are the
same for both the left and right
1.
2.
dummy receptacles.
Using pliers, disconnect electrical
connector (A) of discharger harness (B)
from back of discharger (C).
Using screwdriver, remove four screws (D)
and lockwashers (E) securing dummy
receptacle (F) and gasket (G) to discharger
bracket (H).
3.
Take dummy receptacle (F) and gasket (G)
off discharger bracket (H). Discard
gasket.
Go on to Sheet 2
TA249168
22-27


Back to Top