TM-9-1200-215-34-P

AUTOMATIC FIRE CONTROL SYSTEM (AFCS)

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

FEBRUARY 1999

  TM-9-1200-215-34-P - Page 35 of 266

TM 9–1200–215–34&P
1–23
1–25.
J5 PROTECTIVE COVER MAINTENANCE INSTRUCTIONS
DESCRIPTION
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools:
Tool Kits, JTK–17LAL, TK–101/G, or TK–105/G
(items 34, 35, & 36, Appendix E)
Torque Wrench, 0–15 in.–lb (item 39, Appendix E)
#2 Crosstip Screwdriver Socket
(item 22, Appendix E)
Equipment Condition:
Unenergized LRU is on workbench.
Personnel Required:
One MOS 35Y
NOTE
This is the standard procedure to remove and replace the J5 protective cover on all LRUs that
are so equipped.
Check table 1–2 for listing of LRUs with J5 connectors.
Table 1–2.
LRUs with J5 Connectors
LRU
J5 Connectors
PDIU
Yes
ACU
Yes
DU
No
VMS Modem
No
a.
REMOVAL
1.
Remove J5 protective cover (1) from
connector (2).
2.
Remove screw (3) and flat washer (4) securing
J5 protective cover (1) to bottom cover (5).
b.
INSTALLATION
1.
Install screw (3) and flat washer (4) securing
J5 protective cover (1) to bottom cover (5).
Torque screw to 9.5 + 0.5 in.–lb (1.1 + 0.1
N
S
m).
2.
Install J5 protective cover (1) on connector (2).
Change 1
1
2
5
4
3


Back to Top