3-42
TM 9-1240-401-34&P
3-25. RETICLE CAGE ASSEMBLY MAINTENANCE INSTRUCTIONS (M118A2)
This task covers:
a. Removal b. Repair c. Installation
INITIAL SET-UP
Tools and Special Tools
Spanner wrench, fabricated (fig. C-6, appx C)
Tool Kit, Electronic System, Repair, Field Mainte-
nance (SC5180-95-CL-B29)
aterials/Parts
Grease (Item 7, appx B)
Lockwashers (8) (Item 68, appx E)
Preformed packing (2) (Item 23, appx E)
TM 9-254
M118A2 elbow telescope removed from howitzer
(TM 9-2350-311-10)
Reticle cage and cant corrector subassembly
removed from eyepiece and erector lens subas-
sembly (ref. para 3-21)
a. Removal
1
2
3
4
Remove eight cap screws (1), eight Iockwashers
(2), two access covers (3) and two preformed
packings (4) from both sides of housing (5).
card preformed packings and Iockwashers.
Remove threaded ring (6) from housing (5),
fabricated spanner wrench.
Dis-
using
Remove reticle cage assembly (7) from housing (5)
being careful not to damage wiring harness (8).
Remove machine screw (9) and clamp (10). Re-
lease wiring harness (8) from side of the reticle
cage assembly (7).
b.
Repair
1 Visually inspect for missing or damaged parts.
2 Repair or replace parts in accordance with author-
ized parts listed in appendix D.