TM 9-1240-401-34&P
d. Assembly
Install two sleeve spacers (16), circuit board as-
sembly (15), two new Iockwashers (14), and two
machine screws (13) to reticle cage assembly (7).
e. Installation
1
2
Attach wires of wiring harness (8); black wire to
negative (-) terminal and white wire to positive (+)
terminal on the circuit board assembly (15), using
two new Iockwashers (12) and two nuts (1 1).
Install wiring harness (8) on side of reticle cage
assembly (7) and secure with clamp (10) and
machine screw (9).
3 Install reticle cage assembly (7) in housing (5) be-
ing careful not to damage wiring harness (8).
4 Install threaded ring (6) in housing (5) using fabri-
cated spanner wrench.
5 Apply grease to two new preformed packings (4)
and install in grooves of two access covers (3).
6 Install two access covers (3) on housing (5) and
secure with eight new Iockwashers (2) and eight
cap screws (1).
3-41