ARMY TM 9-1290-365-24&P
SECTION IX. MICROWAVE TEST EQUIPMENT,
DESCRIPTION AND CALIBRATION
SECTION CONTENTS
Subject
Page
General.
.................................................................................................................................................
D-113
Operation Description .
..........................................................................................................................
D-113
Test Equipment Calibration.
.................................................................................................................
D-1 17
D.9.1 General.
D.9.1 .1 SCOPE. This section describes the microwave test equipment (MTE) that is used for testing of
the M93 transceiver assembly P/N’s AY6707292-O, AY6707292-4, and AY6707292-5. This MTE is also
used on testing the M94 transceiver assembly P/N’s AY6706571-O and AY6706571-2. For the M94
transceiver assembly, refer to TM 9-1290-364-24&P, Appendix D, Section 10.
D.9.1.2 PURPOSE. The purpose of this section is to provide the calibration and maintenance procedures
for the MTE.
D.9.2 Operation Description.
D.9.2.1 PURPOSE. The purpose of the MTE is to demonstrate that the RF Section of the transceiver
assembly complies with the requirements.
D.9.2.2 TESTED REQUIREMENTS. The following performance requirements of the transceiver assembly
are tested using the MTE:
a. Transmitted power
b. Transmitted frequency
c. Receiver sensitivity
D.9.2.3 EQUIPMENT DESCRIPTION. The MTE is composed basically of two types of equipment:
a. Standard Measurement Equipment (SME)
b. Microwave Measurement Equipment (MME)
D.9.2.3.1 STANDARD MEASUREMENT EQUIPMENT. Unless otherwise specified, the standard mea-
surement equipment (SME) listed in Table D-24. is used for testing the transceiver assembly. Each SME
can be replaced by equipment equivalent to the one listed with same or better performance.
D-113