FRAME 3
1.
Put gasket (1) between pipe flange (2) and meter flange (3), alining holes.
Put two bolts (4) through pipe flange, gasket, and meter flange.
2.
Using 15/16-inch wrench, hold nuts (5). Using 15/16-inch wrench, screw
in and tighten bolts (4).
3.
Do steps 1 and 2 again for gasket (6) on other side of meter.
4.
Close fuel truck rear compartment door.
END OF TASK
18-244