TM 9-2320-209-20-3-4
FRAME 2
1.
2.
3.
4.
Working from inside cab, put two duct clamps (1) on 29 1/2-inch diverter duct
(2). Put one end of diverter duct on left port of diverter assembly (3) and
put other end of left deflector (4). Slide duct clamps to each end of duct.
Using screwdriver, tighten two duct clamps (1).
Put two duct clamps (5) on 26 1/2-inch diverter duct (6). Put one end of
diverter duct on right port of diverter assembly (3) and put other end on
right deflector (7).
Slide duct clamp to each end of duct.
Using screwdriver, tighten two duct clamps (5).
Close
END OF TASK
NOTE
Follow-on Maintenance Action Required:
hood and left side panel. Refer to TM 9-2320-209-10.
23-6