TM 9-2320-209-34-2-3
FRAME 1
1.
2.
3.
4.
NOTE
If fuel control valve (1) is already off heater, skip
step 1.
Take fuel control valve (1) off heater. Refer to para 21-6c, frame 1, frame
4, and frame 5.
Connect fuel supply line (2) to fuel inlet fitting (3).
Using a suitable electrical lead (4), connect shutoff electrical lead (5) and
restrictive electrical lead (6) together.
Connect other end of lead (4) to
pin B (7) of wiring harness connector (8).
Using another suitable electrical lead (9), connect body of fuel control
valve (1) to pin A ( 10) of wiring harness connector (8).
GO TO FRAME 2
21-3