TM 9-2320-209-34-2-3
FRAME 3
NOTE
A suitable container (3) to catch overflow is needed for
this test.
1. Hold fuel outlet (1) of fuel control valve (2) over overflow container (3).
2. Be sure HI-LO switch (4) is in LO position. Flip control switch (5) to RUN
position.
Fuel pump should be pumping.
3. Flip HI-LO switch (4) to HI. Let fuel flow into overflow container (3) for a
few seconds. Flip HI-LO switch (4) to LO.
4. Look at fuel outlet (1) for one minute. One or two drops may form, but fuel
flow must be completely stopped.
5.
Do steps 1 through 4 again. Flip control switch (5) to OFF position.
6. If fuel flow does not stop completely when HI-LO switch (4) is flipped to LO,
get a new fuel control valve.
IF FUEL CONTROL VALVE PASSES TEST, GO TO FRAME 4.
IF FUEL CONTROL VALVE FAILS TEST, GO TO FRAME 6
21-5