TM 9-2320-209-34-2-3
FRAME 5
1.
Take restrictive electrical lead (1) out of clip (2).
2.
Hold fuel outlet (3) of fuel control valve (4) over overflow container (5).
3.
Be sure HI-LO switch (6) is in LO position. Flip control switch (7) to RUN
position.
Fuel pump should be pumping.
4.
Flip HI-LO switch (6) to HI. Let fuel flow into overflow container (5) for a
few seconds.
5.
Let fuel flow into graduate (8) for exactly one minute. Flip HI-LO switch (6)
to LO. Flip control switch (7) to OFF position.
6.
Place graduate (8) on a level surface. Read level of fuel (9) as shown. Level
of fuel should be as in table for type of fuel used.
FUEL TYPE
Diesel Fuel
Combat
DFA
DF1
DF2
Gasoline
Flow Rate
(cc/mm)
6 to 8
6.5 to 8.5
6.5 to 8.5 7 to 9
7.
If fuel flow is not within range of table, get a new fuel control valve (4).
GO TO FRAME 6
21-7