NO LIGHTS OPERATE WITH DIRECTIONAL SIGNAL CONTROL LEVER IN ANY POSITION - Continued
STEP
6.
IS THERE CONTINUITY BETWEEN TERMINAL B OF THE FLASHER UNIT AND TERMINAL F OF THE
CONTROL UNIT CABLE?
a.
Connect multimeter red lead to terminal F of the control unit cable. Refer to point to point schematics.
T1032DAA
VOM
2
2
3
A
B
C
H
F
1
1
CONTROL
UNIT CABLE
FLASHER
UNIT CABLE
Figure 6.
Flasher Wire Harness Test.
b.
Connect multimeter black lead to terminal B of the flasher units.
c.
Meter reading should be less than 20 ohms.
CONDITION/INDICATION
IS THERE CONTINUITY BETWEEN TERMINAL B OF THE FLASHER UNIT AND TERMINAL F OF THE
CONTROL UNIT CABLE?
DECISION
NO - Repair faulty wire (Volume 3, WP
0352). Go to Step (9) to verify problem is solved.
YES - Go to Step (7).
TM 9-2320-272-23-1
0098
0098-6