INSTALLATION
NOTE
Wrap male pipe threads with antiseize tape before installation.
1.
Install reducer (Figure 2, Item 4), elbow (Figure 2, Item 1), tee (Figure 2, Item 3), nipple (Figure 2, Item 2), and
regulator valve (Figure 2, Item 9) on air horn solenoid (Figure 2, Item 7).
2.
Install air line (Figure 2, Item 6) and adapter (Figure 2, Item 5) on tee (Figure 2, Item 3).
3.
Connect supply hose (Figure 2, Item 8) to regulator valve (Figure 2, Item 9).
M10377DAA
1
2
3
4
5
8
6
3
7
9
8
9
Figure 2.
Deepwater Fording Regulator Valve Installation.
END OF TASK
TM 9-2320-272-23-5
0771
0771-3