3-427. 100-AMP ALTERNATOR HARNESS REPLACEMENT
THIS TASK COVERS:
a. Removal
b. Installation
INlTlAL SETUP:
APPLICABLE MODELS
All
TOOLS
General mechanic’s tool kit (Appendix E, Item 1)
MATERIALS/PARTS
Five tiedown straps (Appendix D, Item 696)
Two lockwashers (Appendix D, Item 379)
Lockwasher (Appendix D, item 416)
REFERENCES (TM)
TM 9-2320-272-10
TM 9-2320-272-24P
EQUIPMENT CONDlTlON
• Parking brake set (TM 9-2320-272-10).
• Hood raised and secured (TM 9-2320-272-10).
• Left and right splash shields removed
(TM 9-2320-272-10).
• Battery ground cables disconnected (para. 3-126).
a. Removal
NOTE
Tag wires, connectors, and cables for installation.
1.
Remove three screws (6), washers (5), and clamps (4) from firewall (2), front wiring harness (22),
and voltage regulator wiring harness (3).
2.
Remove four tiedown straps (7) from front wiring harness (22) and voltage regulator wiring
harness (3). Discard tiedown straps (7).
3.
Remove two nuts (18), washers (17), and clamps (16) from personnel heater (1).
4.
Remove tiedown strap (15) from wiring harness (10). Discard tiedown strap (15).
5.
Disconnect harness connector (8) from alternator (9).
6.
Disconnect connectors (12) and (13) from wires (11) and (14).
7.
Disconnect harness connectors (19) and (21) from regulator (20).
3-1096