TM 9-2320-272-24-2
4-4. POWER PLANT (M939/A1) REPLACEMENT (Contd)
57.
58.
59.
60.
61.
62.
63.
64.
65.
Install hose (13) on water heater shutoff valve (11) with clamp (12).
Install hose (14) on water heater shutoff valve (16) with clamp (15).
Install wire (29) on alternator (30) with washer (28), new lockwasher (27), and nut (26).
Install wire (17) on alternator (30) with washer (18), new lockwasher (19), and nut (20).
Install wire (34) on alternator (30) with new lockwasher (35) and screw (36).
Install wire retaining strap (21) on alternator (30) with two new lockwashers (22) and screws (23).
Seal wires (29) and (17) completely with adhesive sealant, and install terminal cover (24) on
alternator (30) with two new screw-assembled lockwashers (25).
Connect wire (32) to connector (31).
Install new tiedown strap (33) around all wires.