TM 9-2320-272-24-3
4-63. WATER PUMP (M939/A1) MAINTENANCE (Contd)
NOTE
l
This table provides the minimum, maximum, and worn
serviceability standards for the water pump assembly. The wear
limits indicate the point to which a part or parts may be worn
before replacement is required.
l
An asterisk (*) in the wear limits column indicates the part or
parts must be replaced or repaired when worn beyond the
dimensions specified in the “size and fit of new parts” column.
Table 4-8. Repair and Replacement Standards for Water Pump.
REF.
SIZE AND FIT
WEAR
NO.
POINT OF MEASUREMENT
OF NEW PARTS
LIMITS
WATER PUMP BODY
1
Housing bearing bore
2.4408-2.4414 in.
2.4494 in.
(61.996-62.012 mm)
(62.215 mm)
2
Housing bore (impeller end)
1.5000-1.5200 in.
*
water pump body (I.D.)
(38.100-38.608 mm)
Minimum press fit between shaft and
0.001 in.
impeller
(0.03 mm)
3
Drive pulley bore inside diameter (I.D.)
0.663-0.6673 in.
*
(16.84-16.949 mm)
Minimum press fit between shaft and pulley
0.001 in.
(0.03 mm)
SHAFT
4
Shaft diameter (O.D.)
0.6262-0.6267 in.
*
Impeller end
(15.905-15.918 mm)
5
Shaft diameter (O.D.)
0.6262-0.6267 in.
*
Seal seat location
(15.905-15.918 mm)
6
Shaft diameter (O.D.)
0.9843-0.9847 in.
*
Inner bearing
(25.001-25.011 mm)
7
Shaft diameter (O.D.)
0.9843-0.9847 in.
*
Outer bearing
(25.001-25.011 mm)
8
Shaft diameter (O.D.)
0.6693-0.6696 in.
*
Pulley end
(17.002-17.007 mm)
IMPELLER
9
Impeller bore inside diameter (I.D.)
0.624-0.625 in.
*
(15.85-15.88 mm)
10
Impeller vane to pump body clearance
0.020-0.040 in.
*
(cast iron)
(0.51-1.02 mm)
4-382