TM 9-2320-280-20-2
4-124. NBC CONTROL PANEL REPLACEMENT (Cont’d)
NOTE
Leads 785 and 786 have two way jumpers connecting fuses for
heaters 1 & 2 and 3 & 4 respectively.
17. Remove leads 785 (3) and 785A (9) from NBC fuse block (5) for heater fuse #1.
18. Remove lead 785B (8) from NBC fuse block (5) for heater fuse #2.
19. Remove leads 786 (4) and 786A (7) from NBC fuse bock (5) for heater fuse #3.
20. Remove lead 786B (6) from NBC fuse block (5) for heater fuse #4.
21. Remove leads 787 (1) and 787A (2) from NBC fuse block (5) for heater fuse #5.
4-302