TM-9-2320-280-20-3

TRUCK, UTILITY: M998 SERIES

TECHNICAL MANUAL; UNIT MAINTENANCE; VOLUME 3 OF 3

JANUARY 1996

  TM-9-2320-280-20-3 - Page 1069 of 1168

TM 9-2320-280-20-3
D-96
Change 1
Figure D-109. Tip Jack Lead Assembly.
MATERIAL BLOCK
STOCK SIZE
DESCRIPTION
SPECIFICATION
14 AWG
WIRE, ELECTRICAL
MIL-C-13486/1
N/A
INSULATION SLEEVING
MIL-I-23053/5
Section II.
I L L U S T R ATED MANUFACTURING INSTRUCTIONS (Cont'd)
INSTRUCTIONS:
NOT E
When connecting electrical wire to receptacle pins on tip
jacks, use NSN 3493-00-133-1108 solder. (Refer to TB SIG-222
for soldering.)
1. Cut wire (1) into five 12-in. sections as shown.
2. Cut insulation sleeving (3) into five 1-in. sections as shown.
3. Connect five wires (1) to receptacle pins on tip jacks (2).
4. Place insulation sleeving (3) over wires (1) and receptacle pins and heat-shrink insulation sleeving (3)
into position.
I T E M
M AT E R
I A L S
N O .
R E Q ’ D
D E S C R
I P T
I O N
N S N
1
5
Electrical Wire:
12 in.
2
5
Tip Jack
3
5
Insulation Sleeving:
1 in.


Back to Top