TM 9-2320-283-20-1
STE/ICE TROUBLESHOOTING.
2-19.
VEHICLE TESTING TROUBLESHOOTING PROCEDURES (Continued).
(2)
Minimum Value (Test 02).
This test displays the minimum value measured during a test.
To initiate a
minimum value display, dial 02 into the TEST SELECT
switches and press
and release
the TEST
button.
The
prompting message PASS will signal the mechanic to dial the desired test number and again press and release the TEST
button.
The minimum value is displayed and updated whenever a
lower minimum value is measured.
Entering 02
and
the test number again will reset the process and a new minimum value will be displayed.
(3)
Maximum Value (Test 03).
This test displays the maximum value measured during a test.
To initiate a
maximum value display, dial 03 into the TEST SELECT switches and press and release the TEST button.
The maximum
value is displayed and updated whenever a higher maximum value is measured.
Entering 03 and the test number again
will reset the process and a new maximum value will be displayed.
(4)
Peak-to Peak Value (Test 04).
This test displays the peak-to-peak value of alternator/generator output
volts (82), 45 volts DC (89), 1500 amps DC (90), and battery volts (67).
To start a peak-to-peak measurement, dial 04 into
the TEST SELECT switches and press the test button.
The prompting message PASS will signal the operator to dial in
one of the four numbers (82, 89, 90, or 67) and again press the TEST button.
2-346