TM-9-2320-283-20-1

TRUCK TRACTOR, LINE HAUL, 50,000 GVWR, 6X4, M915A1

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE PART 1 OF 3

DECEMBER 1983

  TM-9-2320-283-20-1 - Page 461 of 926

TM 9-2320-283-20-1
STE/ICE TROUBLESHOOTING.
2-16.
STE/ICE DESCRIPTION AND OPERATION (Continued).
(b)
Prompting Message.
A prompting message is any action message to the mechanic.
It is
a signal for
you to
do something such as crank
the engine. For example, UEH tells you to enter the vehicle type identification number
into the VTM.
After the
operator action is performed, the
test will automatically continue.
Prompting messages are listed
on page 2-338.
(c)
Numerical Readout.
A numerical readout is the measured value in units of the
measurement being
made.
For example,
if you are measuring 0-45 VDC, 12.7 is volts dc.
If you are measuring 0-25 psig pressure, 12.7 is
psig.
The units for each test are listed on the flip card.
The numbers displayed in the VTM are always sensitive unless
there is a minus shown to make them negative.
(d)
Error Readout.
E001 is a representative error readout.
There are 17 different error readouts.
All error
readouts start with E.
An error readout is a warning that you forgot to
connect the transducer, selected a
wrong test
number, failed
to start the engine, etc.
All of
the error messages mean you must correct the problem before continuing
testing.
If the error message does
(e)
Confidence Error Readouts.
EUU4 is a representative error readout resulting
from the
detection of a
faulty VTM
during confidence
test.
For detailed information concerning confidence error readouts, refer to TM 9-4910-
571-12&P.
2-336