TM 9-2320-328-13&P-1
0111-3
DRAFT
0111
Change 1
.
HWT0724
.
Step 4.
Install circuit breaker FS 25 (WP 0242).
Push battery disconnect switch to on position
(WP 0007).
Remove cab instrument panel C (WP 0205).
Disconnect cab instrument
panel wire harness REAR SCENE switch connector.
Check for 22 to 28 VDC between
cab instrument panel wire harness wire 2195 (orange) at cab instrument panel wire
harness REAR SCENE switch connector, terminal 6 and a known good ground.
.
If 22 to 28 VDC are present, go to Step 6.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION