TM 9-2320-328-13&P-1
0031-3
DRAFT
0031
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
•
Valve is completely open when green indicator light illuminates.
•
Valve is completely closed when red indicator light illuminates.
7.
Push NO. 1 DRIVER SIDE DISCHARGE valve control OPEN button (9) until green indicator light (10)
illuminates.
8.
Flush water pump clean.
9.
Push NO. 1 DRIVER SIDE DISCHARGE valve control CLOSE button (11) until red indicator light (12)
illuminates.
10. Put HIGH IDLE switch (7) to OFF position.
Indicator light (8) will go out.
11. Put PUMP PTO switch (5) to off position.
Indicator light (6) will go out.
12. Close supply valve on positive water source.
13. Push NO. 1 DRIVER SIDE DISCHARGE valve control OPEN button (9) until green indicator light (10)
illuminates.
14. Push NO. 1 DRIVER SIDE DISCHARGE valve control CLOSE button (11) until red indicator light (12)
illuminates.
HWT2724