TM 9-2320-328-13&P-1
0034-4
DRAFT
0034
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.
Put TANK TO PUMP switch (1) to OPEN position.
Indicator light (2) will illuminate.
4.
Prime water pump (WP 0016).
NOTE
•
Perform Steps (5) and (6) only if Steps (3) and (4) have been completed and pumping
operations will be delayed, and, if mission exceeds a period of 10 minutes.
Partially
opening TANK FILL & RE-CIRCULATING LINE valve control at pump operator’s panel will
recirculate water and help prevent freezing.
•
Go to Step (5) if using an operation that does not use foam.
•
Go to Step (6) if using an operation that uses foam.
5.
Push TANK FILL & RE-CIRCUALTING line valve control OPEN button (3) until green indicator light (4)
illuminates.
6.
Put PUMP COOLER switch (5) to on position.
Indicator light (6) will illuminate.
NOTE
If performing Foam System Operation, Ensure TANK FILL & RE-CIRCULATING LINE
valve control is closed and PUMP COOLER valve is in OPEN position.
7.
Perform desired discharge operation:
•
Pumping from Onboard Water Tank (WP 0019).
•
Foam System Operating Procedures (Cab and Pump Operator’s Panel) (WP 0024).
8.
Complete mission.
HWT1361A