TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 264 of 1318

TM 9-2320-328-13&P-1
0034-6
DRAFT
0034
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Do not open any foam agent supply valves.
This will contaminate water tank.
15. Remove DRIVER SIDE AUX. INLET cap (13), NO. 1 DRIVER SIDE DISCHARGE cap (14), PASSENGER
SIDE AUX. inlet cap (15), NO. 2 PASSENGER SIDE DISCHARGE cap (16), main inlet cap (17), and DIRECT
TANK FILL cap (18).
16. Put WATER TANK DRAIN switch (19) to OPEN position.
Indicator light (20) will illuminate.
17. Put TANK TO PUMP switch (1) to OPEN position.
Indicator light (2) will illuminate.
18. Put DIRECT TANK FILL switch (21) to OPEN position.
Indicator light (22) will illuminate.
19. Put PUMP COOLER switch (5) to ON position.
Indicator light (6) will illuminate.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
HWT3208
HWT1363A


Back to Top