TM 9-2320-328-13&P-1
0059-4
DRAFT
0059
HWT0503
Step 4.
Put cab UNDER TRUCK NOZZLES switch to off position (WP 0004).
Put cab FOAM
SYSTEM switch to on position (WP 0004).
While an assistant puts UNDER TRUCK
NOZZLES switch to on position, check if under truck nozzles foam metering valve
operates to open position.
If under truck nozzles foam metering valve operates to open position,
remove and clean, or replace under truck nozzles foam metering valve
orifice/restrictor (WP 0174).
HWT1258
Step 5.
Put UNDER TRUCK NOZZLES switch to off position (WP 0004).
Check air line from air
control valve manifold to under truck nozzles foam metering valve for kinks and
damage.
If air line is kinked or damaged, replace damaged air line (WP 0374).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top