TM 9-2320-328-13&P-1
0059-5
DRAFT
0059
HWT0504
WARNING
ICON 26,66
•
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
•
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air line at under truck nozzles foam metering
valve and observing air pressure escaping from air line.
When under truck nozzles foam
metering control valve is activated, air will escape from air line.
System air pressure may
drop below 85 psi (586 kPa) during this procedure.
Step 6.
Remove hose reel (WP 0247).
Disconnect air line at under truck nozzles foam
metering valve (WP 0174). While an assistant puts UNDER TRUCK NOZZLES switch
to on position (WP 0004), check if air pressure is present at under truck nozzles foam
metering valve.
If there is air pressure, replace under truck nozzles foam metering valve
(WP 0174).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION