NOTE
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
Do not engage PUMP PTO during this procedure, except when performing complete
system checks.
Valve operations can be checked without water pump operation.
Valve operations can be checked by observing valve shaft rotation.
Valves are open when
tabs or yellow paint tabs are aligned with direction of fluid flow.
Step 2.
Put PUMP COOLER switch to OFF position (WP 0004).
If system air pressure is below
85 psi (586 kPa), start engine and allow system air pressure to build to at least 85 psi
(586 kPa) (TM 9-2320-422-10).
Then shut off engine (TM 9-2320-422-10).
Remove
pump house panel K (WP 0339).
While an assistant puts pump operator’s panel FOAM
FLUSH switch to ON position (WP 0004), check if foam flush valve operates to open
position.
If foam flush valve does not operate to open position, go to Step 12.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top