TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 450 of 1318

TM 9-2320-328-13&P-1
0061-10
DRAFT
0061
HWT0515
WARNING
ICON 26,66
Be sure to wear proper eye protection to prevent injury or death.
If air lines are
under pressure when they are disconnected, they can whip around and cause
injury to personnel.
Caution should be exercised when disconnecting air line
fittings.
Be sure to wear proper eye protection to prevent injury or death.
Air lines may be
under pressure when control valve is operated.
If under pressure and air lines are
disconnected, air lines may whip around and cause injury to personnel.
Caution
should be exercised when operating control valve with air lines disconnected.
NOTE
Air pressure is checked by disconnecting air lines at foam flush valve and observing air
pressure escaping from air line, when foam flush control valve is activated.
Air will escape
from blue air line when FOAM FLUSH switch is put to ON position, and escape from red
air line when FOAM FLUSH switch is put to OFF position.
System air pressure may drop
below 85 psi (586 kPa) during this procedure.
Step 13.
Disconnect air lines at foam flush valve.
While an assistant puts pump operator’s panel
FOAM FLUSH switch to ON and OFF position (WP 0004), check if air pressure is
present at foam flush valve.
If there is air pressure, replace foam flush valve (WP 0179).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION