TM 9-2320-328-13&P-1
0061-14
DRAFT
0061
HWT1019A
Step 18.
Put FOAM FLUSH switch to OFF position (WP 0004).
Pull battery disconnect switch to
off position (WP 0007).
Disconnect main wire harness pump operator’s panel 27-pin
wire harness connector.
With a test lead set, check for continuity across main wire
harness wire 2849 (yellow) from main wire harness pump operator’s panel 27-pin wire
harness connector, terminal 11 to main wire harness pump house wire harness
connector, terminal 1.
a.
If there is continuity, repair wire 2849 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, repair wire 2849 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION