TM 9-2320-328-13&P-1
0062-2
DRAFT
0062
Change 1
..
HWT3067
..
Step 1.
Open pump operator’s panel cover (WP 0010).
Push battery disconnect switch to on
position (WP 0007).
Check if cab and pump operator’s panel FOAM A level gauges
illuminate (WP 0004).
..
If cab and pump operator’s panel FOAM A level gauges do not illuminate,
troubleshoot Foam/Water Level Gauge(s) Does Not Illuminate (WP 0118).
..
..
..
..
..
..
..
NOTE
Foam tank needs to be full to properly test pump operator’s panel FOAM A tank level
gauge for this step.
..
..
..
..
Step 2.
With foam tank filled (WP 0022), check if pump operator’s panel FOAM A level gauge
reads full.
If pump operator’s panel FOAM A level gauge does not read full, perform
Pump Operator’s Panel Foam Level Gauge Calibration (WP 0211).
..
NOTE
Drain foam tank to properly test pump operator’s panel FOAM A level gauge for this
Step.
..
Step 3.
With foam tank drained (WP 0022), check if pump operator’s panel FOAM A level
gauge reads full.
..
If pump operator’s panel FOAM A level gauge reads full, go to Step 21.
..
Step 4.
Check if cab FOAM A level gauge 1/4 and 3/4 LEDs flash alternately.
..
If cab FOAM A level gauge 1/4 and 3/4 LEDs flash alternately, go to
Step 17.
..
Step 5.
Check if pump operator’s panel FOAM A level gauge E and F LEDs flash alternately.
..
If pump operator’s panel FOAM A level gauge E and F LEDs flash
alternately, go to Step 7.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION