TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 610 of 1318

TM 9-2320-328-13&P-1
0069-2
DRAFT
0069
Change 1
..
HWT0898
..
NOTE
Ensure batteries are fully charged before performing Step 1.
..
Step 1.
Push battery disconnect switch to on position (WP 0007).
Check if pump operator’s
panel NO. 2 PASSENGER SIDE DISCHARGE valve control display illuminates.
..
If display is not illuminated, go to Step 18.
..
Step 2.
Check if pump operator’s panel NO. 2 PASSENGER DISCHARGE valve control
displays a negative or positive pressure or a flow reading after No. 2 discharge line is
drained.
..
If pump operator’s panel NO. 2 PASSENGER DISCHARGE valve control
displays a negative or positive pressure, or a flow reading, perform Pump
Operator’s Panel Electric Valve Controller Calibration (WP 0210).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top