Step 17.
Disconnect No. 1 driver side discharge flow sensor (WP 0250) and connect it directly to
NO. 1 DRIVER DISCHARGE valve control (removing flow sensor wire harness from
circuit).
While an assistant spins flow sensor paddle wheel, check if a flow reading is
displayed when the flow sensor paddle is spinning.
.
a.
If a flow reading is displayed when flow sensor paddle is spinning,
repair flow sensor wire harness if repairable (TM 9-2320-325-14&P), or
replace No. 1 driver side discharge flow sensor wire
harness (WP 0294).
.
b.
If a flow reading is not displayed when flow sensor paddle is spinning,
replace No. 1 driver side discharge flow sensor (WP 0250).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION