TM 9-2320-328-13&P-1
0068-9
DRAFT
0068
Change 1
.
HWT0590A
.
Step 13.
Connect valve control wire harness connector to No. 1 driver side discharge valve
motor.
Disconnect valve control wire harness connector from PASSENGER AUX.
INLET valve control.
Connect No. 1 driver side discharge valve control wire harness
connector to PASSENGER SIDE AUX. INLET valve control.
While an assistant pushes
pump operator’s panel PASSENGER SIDE AUX. INLET valve control OPEN and
CLOSE buttons (WP 0004), check if No. 1 driver side discharge valve operates.
.
a.
If No. 1 driver side discharge valve operates, reconnect valve control
wire harness connectors to original positions and replace NO. 1
DRIVER SIDE DISCHARGE valve control (WP 0210).
.
b.
If No. 1 driver side discharge valve does not operate, reconnect valve
control wire harness connectors to original positions and replace No. 1
driver side discharge valve motor (WP 0248).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION