TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 626 of 1318

TM 9-2320-328-13&P-1
0069-18
DRAFT
0069
Change 1
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
..
HWT0571
..
Step 22.
Disconnect pump house wire harness pump house power distribution wire harness
connector DP2.
With a test lead set, check for 22 to 28 VDC between pump house
power distribution wire harness wire 4077 (blue) at connector DP2, terminal C and a
known good ground.
..
a.
If 22 to 28 VDC are present, repair wire 4077 in pump house wire
harness if repairable (TM 9-2320-325-14&P), or replace pump house
wire harness (WP 0292).
..
b.
If 22 to 28 VDC are not present, repair wire 4077 in pump house power
distribution wire harness if repairable (TM 9-2320-325-14&P), or
replace pump house power distribution wire harness and block
(WP 0299).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top