TM 9-2320-328-13&P-1
0072-95
DRAFT
0072
Change 1
..
HWT2653
..
NOTE
•
To locate correct datalink cable connector in cab, follow yellow banded datalink cable from
main wire harness cab pressure governor control connector to first Y connector in series.
•
To locate correct datalink cable connector in pump operator’s panel, follow yellow banded
datalink cable from pump operator’s panel pressure governor control connector to first Y
connector in series.
..
Step 116.
Remove cab instrument panel E (WP 0339).
Disconnect main wire harness datalink
cable connector from CAT datalink Y connector.
Disconnect pump operator’s panel
wire harness datalink cable connector from CAT datalink Y connector.
With a test lead
set, check for continuity across CAT datalink cable CAT Lo wire (green) from CAT
datalink cable Y connector (that was disconnected from main wire harness), terminal B
to CAT datalink cable Y connector (that was disconnected from pump operator’s panel
wire harness), terminal B.
..
If there is no continuity, replace CAT datalink wire harness
(TM 9-2320-325-14&P).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION