To locate correct datalink cable connector in pump house, follow yellow banded datalink
cable from main wire harness cab pressure governor control connector to first Y connector
in series.
..
Step 121.
Disconnect pump house wire harness datalink cable connector from CAT datalink Y
connector.
With a test lead set, check for continuity across CAT datalink cable CAT Lo
wire (green) from CAT datalink cable Y connector (that was disconnected from pump
house wire harness), terminal B to main wire harness cab pressure governor control
connector, terminal 9.
..
a.
If there is continuity, repair pump house wire harness datalink cable if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
..
b.
If there is no continuity, replace CAT datalink wire harness
(TM 9-2320-325-14&P).
..