TM 9-2320-328-13&P-1
0072-107
DRAFT
0072
Change 1
..
Step 130.
Put PUMP PTO switch to off position (WP 0004).
Stop ENGINE (TM 9-2320-422-10).
Check for continuity across wire 1640 from cab power distribution block relay 14,
terminal 1 to a known good ground.
..
a.
If there is no continuity, replace relay 14 (WP 0244).
..
b.
If there is no continuity, repair wire 1640 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
..
HWT2954
..
Step 131.
Put PUMP PTO switch to off position (WP 0004).
Stop engine (TM 9-2320-422-10).
Disconnect cab power distribution cab instrument panel connector.
With a test lead set,
check for continuity across wire 1677 (white) from cab power distribution block relay 14,
terminal 2 to cab power distribution wire harness cab instrument panel connector,
terminal 16.
..
a.
If there is continuity, repair wire 1677 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0279).
..
b.
If there is no continuity, repair wire 1677 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION