Step 137.
Disconnect main wire harness main 1 connector.
WIth a test lead set, check for
continuity across main wire harness wire 3114 from main wire harness main 1
connector, terminal 15 to main wire harness pump house connector, terminal 10.
..
a.
If there is continuity, repair wire 3114 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
..
b.
If there is no continuity, repair wire 3114 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
..