TM 9-2320-328-13&P-1
0074-4
DRAFT
0074
Change 1
.
HWT2975
.
WARNING
.
ICON 72
.
•
Be careful when using high air pressure.
High air pressure can blow out parts,
hoses, or debris with force.
•
Air pressure should not exceed 50 PSI (345 kPa) during procedure.
Failure to
comply may result in damage to equipment. Failure to comply may result in injury
to personnel.
.
NOTE
•
Do not open any valves during this procedure, except have an assistant maintain 50 PSI
(345 kPa) during test.
•
Check all valves to ensure that more than one valve is not leaking.
•
Ensure system air pressure is at least 85 PSI (586 kPa) during this procedure.
.
Step 4.
Check if air can be heard escaping from pump cooler drain line.
.
If air can be heard escaping from pump cooler drain line, replace pump
cooler (dump-to–ground) valve (WP 0319).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION