TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 818 of 1318

TM 9-2320-328-13&P-1
0074-4
DRAFT
0074
Change 1
.
HWT2975
.
WARNING
.
ICON 72
.
Be careful when using high air pressure.
High air pressure can blow out parts,
hoses, or debris with force.
Air pressure should not exceed 50 PSI (345 kPa) during procedure.
Failure to
comply may result in damage to equipment. Failure to comply may result in injury
to personnel.
.
NOTE
Do not open any valves during this procedure, except have an assistant maintain 50 PSI
(345 kPa) during test.
Check all valves to ensure that more than one valve is not leaking.
Ensure system air pressure is at least 85 PSI (586 kPa) during this procedure.
.
Step 4.
Check if air can be heard escaping from pump cooler drain line.
.
If air can be heard escaping from pump cooler drain line, replace pump
cooler (dump-to–ground) valve (WP 0319).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION