  TM-9-2320-328-13-P-1 - Page 968 of 1318

TM 9-2320-328-13&P-1
0086-6
DRAFT
0086
HWT0615
Step 9.
Remove cab instrument panel C (WP 0205).
Disconnect cab instrument panel wire
harness switch connector from non-operating switch connector.
Check for 22 to 28
VDC between cab instrument panel wire harness wire 1018 (violet) at non-operating
cab instrument panel wire harness switch connector, terminal 7 and a known good
ground.
If 22 to 28 VDC are not present, repair wire 1018 in cab instrument panel
wire harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0279).
Step 10.
Turn Service Drive Lights Off (TM 9-2320-422-10).
Pull battery disconnect switch to off
position (WP 0007).
Check for continuity across cab instrument panel wire harness
wire 1027 (black) from non-operating cab instrument panel wire harness switch
connector, terminal 8 to a known good ground.
a.
If there is continuity, replace non-operating rocker switch (WP 0199).
b.
If there is no continuity, repair wire 1027 in cab instrument panel wire
harness if repairable (TM 9-2320-325-14&P), or replace cab instrument
panel wire harness (WP 0279).
Step 11.
Check if backlights on cab instrument panel switches illuminate.
If backlights on cab instrument panel switches do not illuminate, go to
Step 14.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION