TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 970 of 1318

TM 9-2320-328-13&P-1
0086-8
DRAFT
0086
HWT1240
Step 13.
Remove cab instrument panel A (WP 0205). Disconnect cab pump control wire harness
cab power distribution wire harness connector.
With a test lead set, check for 22 to 28
VDC between cab power distribution wire harness wire 1018 (violet) at cab power
distribution wire harness connector, terminal F and a known good ground.
a.
If 22 to 28 VDC are present, repair wire 1018 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump
control wire harness (WP 0279).
b.
If 22 to 28 VDC are not present, repair wire 1018 in cab power
distribution wire harness if repairable (TM 9-2320-325-14&P), or
replace cab power distribution wire harness and block (WP 0280).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top