TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 971 of 1318

TM 9-2320-328-13&P-1
0086-9
DRAFT
0086
HWT1462A
NOTE
Wire numbers with H prefix indicate that circuit is an extension of a HEMTT circuit.
Step 14.
Remove cab instrument panel A (WP 0205).
Remove relay 7 (WP 0244).
Check for 22
to 28 VDC between cab power distribution wire harness wire H052 (white) at relay 7
connector, terminal 1 and a known good ground.
If 22 to 28 VDC are not present, go to Step 19.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION