Step 27.
Pull battery disconnect switch to off position (WP 0007). With a test lead set, check for
continuity across pump house heater diagnostic module connector, terminals A and B
when DIESEL HEATER TEST switch is in on position (WP 0004).
If there is no continuity, go to Step 29.
HWT2223A
Step 28.
Remove pump house panel G (WP 0339). Disconnect pump house wire harness pump
house heater three terminal connector. With a test lead set, check for continuity across
wire 1640 (black) from pump house wire harness pump house heater three terminal
connector, terminal C to a known good ground.
a.
If there is continuity, replace pump house heater (WP 0310).
b.
If there is no continuity, repair wire 1640 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION