Step 22.
Install circuit breaker P 4 (WP 0262). Remove pump house panel G (WP 0339).
Disconnect pump house wire harness pump house heater three terminal connector.
Push battery disconnect switch to on position (WP 0007). Check for 22 to 28 VDC
between wires 2454 (green) at pump house wire harness pump house heater three
terminal connector, terminals A and B, and a known good ground.
a.
If 22 to 28 VDC are not present at both terminals, go to Step 25.
b.
If 22 to 28 VDC are present at one but not both terminals, repair wire
2454 in pump house wire harness if repairable (TM 9-2320-325-14&P),
or replace pump house wire harness (WP 0302).
c.
If 22 to 28 VDC are present at both terminals, go to Step 23.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION