TM 9-2320-328-13&P-2
0127-9
DRAFT
0127
HWT2598
Step 14.
Pull battery disconnect switch to off position (WP 0007).
Remove pump house panel G
(WP 0339).
Disconnect pump house wire harness pump house heater two terminal
connector.
With a test lead set, check for continuity across wire 4089 (green) from
pump house wire harness pump house heater two terminal connector, terminal 1 to
main wire harness pump house heater fuel pump, terminal.
If there is continuity, replace pump house heater (WP 0310).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION