TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 225 of 1390

TM 9-2320-328-13&P-2
0127-5
DRAFT
0127
HWT2213
WARNING
ICON 13
Diesel heater exhaust tube becomes very hot during operation. Do not touch or
allow body to come in contact with exhaust tube when hot. Allow sufficient time for
diesel heater exhaust tube to cool before performing any maintenance to system.
Failure to comply may cause injury or death to personnel.
Step 9.
If on, put DIESEL HEATER TEST switch to off position (WP 0004). If on, pull battery
disconnect switch to off position (WP 0007). Remove pump house panel E (WP 0339).
After system cools, check pump house heater intake and exhaust ports for blockage.
a.
If pump house heater intake or exhaust ports are blocked, remove
blockage.
b.
If pump house heater intake and exhaust ports are not blocked, replace
pump house heater (WP 0310).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top