Step 29.
Check for continuity across pump house heater diagnostic module wire 2852 (red) from
pump house diagnostic module connector, terminal A to thermostatic switch center post
(red wire) terminal.
If there is no continuity, repair wire 2852 if repairable
(TM 9-2320-325-14&P), or replace pump house heater diagnostic module
(WP 0307).
Step 30.
Check for continuity across pump house heater diagnostic module DIESEL HEATER
TEST switch when in on position (WP 0004).
If there is no continuity, replace pump house heater diagnostic module
DIESEL HEATER TEST switch (WP 0306).
Step 31.
Check for continuity across pump house heater diagnostic module wire 2852 (red) from
thermostatic switch center post (red wire) terminal to DIESEL HEATER TEST switch.
a.
If there is continuity, repair black jumperwire between DIESEL HEATER
TEST switch and thermostatic switch if repairable
(TM 9-2320-325-14&P), or replace pump house heater diagnostic
module (WP 0307).
b.
If there is no continuity, repair wire 2852 if repairable
(TM 9-2320-325-14&P), or replace pump house heater diagnostic
module (WP 0307).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION