TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 379 of 1390

TM 9-2320-328-13&P-2
0143-1
DRAFT
0143
FIELD LEVEL MAINTENANCE
HYDRAULIC PRESSURE CONTROL REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Position drain pan under hoses and valve.
Tag and mark hoses prior to removal to ensure proper installation.
Cap and plug hoses upon removal.
Hoses 1, 4, and 7 have same hose number.
1.
Remove hose 1682914 (1) and preformed packing (2) from elbow (3).
Discard preformed packing.
2.
Remove hose 1682914 (4) and preformed packing (5) from elbow (6).
Discard preformed packing.
3.
Remove hose 1682914 (7) and preformed packing (8) from elbow (9).
Discard preformed packing.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT1810
Tools and Special Tools
Cap Set, Protective (WP 0398, Item 1)
Drain Pan (WP 0398, Item 4)
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Oil, Lubrication, (WP 0400, Item 20)
Tags, Identification (WP 0400, Item 23)
Preformed Packing (1)
Preformed Packing (1)
Preformed Packing (1)
Materials/Parts (continued)
Lockwasher (2)
Preformed Packing (1)
Preformed Packing (1)
Preformed Packing (1)
Lockwasher (2)
References
WP 0391, Fig. 15
Equipment Conditions
Pump operator’s panel opened (WP 0207)