TM 9-2320-328-13&P-2
0143-6
DRAFT
0143
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7.
Lightly lubricate preformed packing (8) with clean oil, and install preformed packing (8) and hose 1682914 (7)
on elbow (9).
8.
Lightly lubricate preformed packing (5) with clean oil, and install preformed packing (5) and hose 1682914 (4)
on elbow (6).
9.
Lightly lubricate preformed packing (2) with clean oil, and install preformed packing (2) and hose 1682914 (1)
on elbow (3).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump operator’s panel (WP 0207)
END OF TASK
END OF WORK PACKAGE
HWT1810