TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 391 of 1390

TM 9-2320-328-13&P-2
0147-1
DRAFT
0147
FIELD LEVEL MAINTENANCE
HYDRAULIC RESERVOIR FLUID LEVEL SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Hydraulic reservoir fluid level switch is located on driver side of hydraulic reservoir.
Note position of switch prior to removal to ensure proper installation.
1.
Disconnect pump house wire harness connector (1) from hydraulic reservoir fluid level switch connector (2).
2.
Remove hydraulic reservoir fluid level switch (3) from hydraulic reservoir (4).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2793
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Tape, Teflon (WP 0400, Item 25)
References
WP 0391, Fig. 10
Equipment Conditions
Pump house panel K access panel
opened (WP 0008)
Hydraulic reservoir drained (WP 0145)


Back to Top