INSTALLATION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Install switch as noted prior to removal.
1.
Apply teflon tape to threads of hydraulic reservoir fluid level switch (3).
2.
Install hydraulic reservoir fluid level switch (3) in hydraulic reservoir (4).
3.
Connect pump house wire harness connector (1) on hydraulic reservoir fluid level switch connector (2).
END OF TASK
FOLLOW-ON MAINTENANCE
Fill hydraulic reservoir (WP 0145)
END OF TASK